Hi all,
 
i have a nsrp cluster with 2 members. All interfaces are monitored, and if one interface is lost, it fails over.
I shut an interface down on first member using CLI : set i e1/1 link-phys down
 
Is it replicated on the second member ?
Does the cluster fail over ?(does the second member become active ?)
 
Thanks for your help.
 
Arno Mesguich
Security Engineer
Service : technique
Email : arno.mesguich@...
Tél : +33 (0)1 41 85 10 30
Fax : +33 (0)1 41 85 10 21


Besoin de ressources techniques ?


NOXS France
9 - 11 Allée des Pierres Mayettes
92632 GENNEVILLIERS Cedex
Web : http://www.noxs.fr
 



_______________________________________________
nn mailing list
nn@...
http://qorbit.net/mailman/listinfo/nn

Re: Nsrp question

by dh-7 :: Rate this Message:

Reply (Restricted by the Administrator) | Reply to Author | View Threaded | Show Only this Message

Yes, it will initiate a failover, and the command is:
set int x/x phy link-down

/dh


Arno MESGUICH wrote:

> Hi all,
>  
> i have a nsrp cluster with 2 members. All interfaces are monitored,
> and if one interface is lost, it fails over.
> I shut an interface down on first member using CLI : set i e1/1
> link-phys down
>  
> Is it replicated on the second member ?
> Does the cluster fail over ?(does the second member become active ?)
>  
> Thanks for your help.
>  
> *Arno Mesguich*
> Security Engineer
> Service : technique
> Email : arno.mesguich@... <mailto:arno.mesguich@...>
> Tél : +33 (0)1 41 85 10 30
> Fax : +33 (0)1 41 85 10 21
>
>
> Besoin de ressources techniques ?
> <http://www.noxs.fr/services/partner-services/xteam-request/>
>
>
> *NOXS France*
> 9 - 11 Allée des Pierres Mayettes
> 92632 GENNEVILLIERS Cedex
> Web : http://www.noxs.fr <http://www.noxs.fr/>
>
> <http://www.noxs.fr/>
>
>  
> ------------------------------------------------------------------------
>
> _______________________________________________
> nn mailing list
> nn@...
> http://qorbit.net/mailman/listinfo/nn
>  

_______________________________________________
nn mailing list
nn@...
http://qorbit.net/mailman/listinfo/nn

Re: Nsrp question

by Tim E :: Rate this Message:

Reply (Restricted by the Administrator) | Reply to Author | View Threaded | Show Only this Message

Some parts of this message have been removed. Learn more about Nabble's security policy.
And no, it will not be replicated to the second member.

Incase you were wondering.. To bring the underface back up:

unset int x/x phy link-down

-Tim Eberhard

On 3/26/07, Arno MESGUICH <arno.mesguich@...> wrote:
Hi all,
 
i have a nsrp cluster with 2 members. All interfaces are monitored, and if one interface is lost, it fails over.
I shut an interface down on first member using CLI : set i e1/1 link-phys down
 
Is it replicated on the second member ?
Does the cluster fail over ?(does the second member become active ?)
 
Thanks for your help.
 
Arno Mesguich
Security Engineer
Service : technique
Email : arno.mesguich@...
Tél : +33 (0)1 41 85 10 30
Fax : +33 (0)1 41 85 10 21


Besoin de ressources techniques ?


NOXS France
9 - 11 Allée des Pierres Mayettes
92632 GENNEVILLIERS Cedex
Web : http://www.noxs.fr

 

_______________________________________________
nn mailing list
nn@...
http://qorbit.net/mailman/listinfo/nn





_______________________________________________
nn mailing list
nn@...
http://qorbit.net/mailman/listinfo/nn
LightInTheBox - Buy quality products at wholesale price